skip to main content

Peninjauan Keandalan Sistem Pentanahan Tower SUTT 150 kV Jakabaring-Keramasan Terhadap Arus Gangguan

*Junaedi Junaedi  -  Program Studi Program Profesi Insinyur Fakultas Teknik, Universitas Diponegoro,, Indonesia
Aris Triwiyatno  -  Program Studi Program Profesi Insinyur Fakultas Teknik, Universitas Diponegoro,, Indonesia
Sumardi Sumardi  -  Program Studi Program Profesi Insinyur Fakultas Teknik, Universitas Diponegoro,, Indonesia
Received: 13 Nov 2024; Revised: 7 Dec 2024; Accepted: 9 Dec 2024; Available online: 10 Dec 2024; Published: 12 Dec 2024.

Citation Format:
Abstract

Untuk menjaga keandalan proses penyaluran energi listrik dari arus gangguan, proteksi yang digunakan di antaranya adalah sistem pentanahan pada tower-tower Saluran Udara Tegangan Tinggi (SUTT). Penelitian ini bertujuan untuk meninjau atau mengevaluasi SUTT 150 kV Section Jakabaring-Keramasan dikarenakan SUTT ini melewati permukiman dan lahan pertanian masyarakat, tentunya dengan sistem proteksi pentanahan sangat diandalkan melindungi tower dan mahluk hidup dari induksi tegangan listrik maupun dampak sambaran petir. Dari hasil pengukuran resistansi pentanahan di tower SUTT 150 kV masih relatif aman di mana nilai resistansi pentanahan masih dibawah 5 Ω, termasuk dari hasil perhitungan. Dari analisa resistansi pentanahan dengan kondisi tanah memiliki struktur dua lapis melalui Cymgrd dimana potesial terjadinya tegangan langkah ditimbulkan sebesar 208,34 volt dan potensial terjadinya tegangan sentuh 175,12 volt. Sedangkan dari konstruksi sistem pentanahan terpasang melalui simulasi Cymgrd bahwa konstruksi pentanahan sekarang termasuk andal dan mampu meminimalisir Ground Potential Rise (GPR) di sekitar kaki tower menjadi 4,50477 volt dari besarnya arus gangguan yang mencapai 3760 ampere dan dinyatakan masih relatif aman bagi mahluk hidup di permukaan tanah pada lokasi tower.

 

Kata kunci: sistem pentanahan tower, SUTT 150 kV, arus gangguan, keandalan

Fulltext View|Download

Article Metrics:

  1. Arfianto, T., & Salam, A. I. (2019). Analisis Tahanan Pentanahan Kaki Tower SUTT 70 kV Rute Cigereleng-Majalaya. Jurnal PROtek Vol, 6(1)
  2. Chen, Y., Wei, Y., Cao, J., Wang, X., Wang, J., Zhang, J., ... & Liu, W. (2024). Characteristic of power-transmission-induced current and power loss on the OPGW of 750 kV transmission line system. Electric Power Systems Research, 229, 110130
  3. Datsios, Z. G., Stracqualursi, E., Patsalis, D. G., Araneo, R., Mikropoulos, P. N., & Tsovilis, T. E. (2023). Evaluation of the Backflashover Performance of a 150 kV Overhead Transmission Line Considering Frequency-and Current-Dependent Effects of Tower Grounding Systems. IEEE Transactions on Industry Applications
  4. Faudzi, A. H. M., Wooi, C. L., Ahmad, N. A., Arshad, S. N. M., Afrouzi, H. N., & Rohani, M. N. K. (2020). A study on copper and galvanized grounding performance using palm oil fuel ash as new additive material. In Journal of Physics: Conference Series (Vol. 1432, No. 1, p. 012037). IOP Publishing
  5. Harijanto, P. S., Raganingrum, E., & Prasetyo, B. E. (2021). Uji Performa Pengaman Gangguan Petir Pada Saluran Transmisi 70 kV GI Kebonagung–GI Polehan Menggunakan ATP DRAW. Elposys: Jurnal Sistem Kelistrikan, 8(2), 66-71
  6. IEEE Std 81. (2012). IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System Sponsored by the Substations Committee IEEE Power and Energy Society (Vol. 2012, Issue December)
  7. Manalu, A. R., Danial, D., & Rajagukguk, M. Evaluation of Cloud to Ground Flash Density of 150 kV Transmission Line Between Parit Baru Substation and Senggiring Substatio. Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL), 1(3), 261-270
  8. Permal, N., Osman, M., Ariffin, A. M., & Ab Kadir, M. Z. A. (2021). The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters. IEEE Access, 9, 37497-37509
  9. Putra, D. E., Pardede, G. P., Kurniawan, F., Saputra, M. W., Sinaga, R., Rahmanda, A., ... & Salis, M. W. (2023). Comparison of Grounding Resistance Using Grounding Rod Electrodes with Different Fault Current Types in Podzolic Soil at Prabumulih Substation. Journal of Renewable Energy, Electrical, and Computer Engineering, 3(1), 19-25
  10. Putra, D. E., Randika, Y., Randika, I., Inamullah, H., Rusdiansyah, A., & Raharjo, W. (2024). Enhancing grounding system efficiency through biopore technique in seasonal soil conditions. International Journal of Advanced Technology and Engineering Exploration, 11(113), 516
  11. Putra, D. E., Yani, R. A., Siahan, M. S., Rizal, C., & Nofiansah, N. (2023). The Decreasing Ground Potential Rise By Lessening Soil Resistance In Arrester Grounding System. IJEEIT: International Journal of Electrical Engineering and Information Technology, 6(2), 44-50
  12. Salam, M. A., Rahman, Q. M., Ang, S. P., & Wen, F. (2017). Soil resistivity and ground resistance for dry and wet soil. Journal of Modern Power Systems and Clean Energy, 5(2), 290-297
  13. SPLN T5.012. (2020). Earthing at Substations and Transmission Networks (Issue 0053)
  14. Wen, X., Jing, M., Cai, H., Zhang, Y., Hu, S., Teng, Y., ... & Lu, H. (2020). Temperature characteristics and influence of water-saturated soil resistivity on the HVDC grounding electrode temperature rise. International Journal of Electrical Power & Energy Systems, 118, 105720

Last update:

No citation recorded.

Last update: