Laboratorium Sentral, Universitas Padjadjaran, Jl. Raya Bandung Sumedang Km. 21 Jatinangor, Indonesia
BibTex Citation Data :
@article{JPLP16838, author = {Ida Farida and Annisa Muliya}, title = {Validasi Kurkumin Hasil Isolasi Rimpang Kunyit Dengan Kromatografi Cair Kinerja Tinggi Photodiode Array Detector}, journal = {Jurnal Pengelolaan Laboratorium Pendidikan}, volume = {5}, number = {2}, year = {2023}, keywords = {Curcumin, HPLC-PDA, Validation}, abstract = { Curcumin is the main compound in turmeric and has problems in its stability. The analytical method used to determine curcumin levels is by using high performance liquid Chromatography (HPLC) Photodiode Array Detector (PDA) . HPLC has a high separation capability and good reproducibility with a low detection limit. The purpose of this research is that the isolation curcumine determined by HPLC-PDA and has been validated can be applied as a standard in quantitative analysis in the laboratory. The validation parameters specified include accuracy, precision, linearity, detection limits and quantification limits. The results of HPLC-PDA research used acetonitrile mobile phase condition : buffer phosphate pH 3,5 (70:30 v/v), flow rate of 1 mL/min, wavelength 426 nm showed curcumin from isolation had resolution (Rs= 5.7172), linearity (r=0.9991), accuracy (0.5 and 1 ppm), presicion at a concentration of 5 ppm %RSD < 20.0%, and BD values also BK are 0.1122 and 0.3401 ppm. Validation of curcumin from isolation using HPLC-PDA has the requirements as a good validation and can be used as a reference in the laboratory. }, issn = {2654-251X}, pages = {50--57} doi = {10.14710/jplp.5.2.50-57}, url = {https://ejournal2.undip.ac.id/index.php/jplp/article/view/16838} }
Refworks Citation Data :
Curcumin is the main compound in turmeric and has problems in its stability. The analytical method used to determine curcumin levels is by using high performance liquid Chromatography (HPLC) Photodiode Array Detector (PDA). HPLC has a high separation capability and good reproducibility with a low detection limit. The purpose of this research is that the isolation curcumine determined by HPLC-PDA and has been validated can be applied as a standard in quantitative analysis in the laboratory. The validation parameters specified include accuracy, precision, linearity, detection limits and quantification limits. The results of HPLC-PDA research used acetonitrile mobile phase condition : buffer phosphate pH 3,5 (70:30 v/v), flow rate of 1 mL/min, wavelength 426 nm showed curcumin from isolation had resolution (Rs= 5.7172), linearity (r=0.9991), accuracy (0.5 and 1 ppm), presicion at a concentration of 5 ppm %RSD < 20.0%, and BD values also BK are 0.1122 and 0.3401 ppm. Validation of curcumin from isolation using HPLC-PDA has the requirements as a good validation and can be used as a reference in the laboratory.
Article Metrics:
Last update:
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Jurnal Pengelolaan Laboratorium Pendidikan and Laboratorium Technical Service Unit Integrated Laboratory Diponegoro University as publisher of the journal.
Copyright encompasses exclusive rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms and any other similar reproductions, as well as translations. The reproduction of any part of this journal, its storage in databases and its transmission by any form or media, such as electronic, electrostatic and mechanical copies, photocopies, recordings, magnetic media, etc. , will be allowed only with a written permission from Jurnal Pengelolaan Laboratorium Pendidikan and Laboratorium.
Jurnal Pengelolaan Laboratorium Pendidikan was published Technical Service Unit Integrated Laboratory Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Jurnal Pengelolaan Laboratorium Pendidikan are sole and exclusive responsibility of their respective authors and advertisers.
Jurnal Pengelolaan Laboratorium Pendidikan (JPLP, e-ISSN: 2654-251X) is published by Persatuan Pranata Laboratorium Pendidikan Universitas Diponegoro.Unit Pelaksana Teknis (UPT) Integrated Laboratory, Universitas Diponegoro Jl. Prof. Soedarto, S.H. Tembalang, Semarang, Jawa Tengah, Indonesia 50275Phone: +6281321906666Email: jplp@live.undip.ac.id View statistics