BibTex Citation Data :
@article{JPA20537, author = {Javaid Ali and Muhammd Sohail and Abdul Samad and Israr Ahmad and Hafeezullah Soomro and Ghufran Biradar and Irum Naz and Imadullah Tariq}, title = {Comparison of Percentage Depth Doses with the Published Data for Co-60 Radiotherapy Machine at a Regional Cancer Hospital}, journal = {Journal of Physics and Its Applications}, volume = {6}, number = {1}, year = {2023}, keywords = {Water phantom, Spirit level, electrometer, Co-60 Machine, PDD.}, abstract = { In external beam radiation therapy, the percentage depth dose (PDD) is a main factor for estimation of patient’s dose and dose distribution in target volume, therefore its accurate estimation is important. The purpose of this article is to compare PDDs with the published PDDs of different authors along central axis at different depths and field sizes for cobalt-60 (Co-60) radiotherapy machine at a regional cancer hospital Pakistan. A dedicated water phantom was used for estimation of PDDs at different depths and different field sizes, for Theratron phoenix Co-60 machine. It was observed that for 10×10 cm 2 filed size of Co-60 beam mean percent variation in measured PDDs and published PDDs by different authors was -0.29% to 1.13%, which was within acceptable limit of ± 2%. However, for one author who used semi-empirical equation for PDDs calculation, the mean percent variation between measured PDDs and that of the author was -3.23%, 4.69% and 5.88% for 10×10 cm 2 , 25×25 cm 2 and 30×30 cm 2 field sizes of Co-60 beam respectively, which were within acceptable limit of ±10%. A noticeable increase in PDDs was observed with increase of the field size at given depth which shows obvious contribution of secondary scattered radiation. Also measured PDDs were well matched with that of published PDDs of most of the authors i.e. ± 2%, but the measured PDDs were moderately matched with that of PDDs for only one author for some field sizes and some depths i.e. ±10%, which need to be rectified by taking more such data. }, issn = {2622-5956}, pages = {24--30} doi = {10.14710/jpa.v6i1.20537}, url = {https://ejournal2.undip.ac.id/index.php/jpa/article/view/20537} }
Refworks Citation Data :
In external beam radiation therapy, the percentage depth dose (PDD) is a main factor for estimation of patient’s dose and dose distribution in target volume, therefore its accurate estimation is important. The purpose of this article is to compare PDDs with the published PDDs of different authors along central axis at different depths and field sizes for cobalt-60 (Co-60) radiotherapy machine at a regional cancer hospital Pakistan. A dedicated water phantom was used for estimation of PDDs at different depths and different field sizes, for Theratron phoenix Co-60 machine. It was observed that for 10×10 cm2 filed size of Co-60 beam mean percent variation in measured PDDs and published PDDs by different authors was -0.29% to 1.13%, which was within acceptable limit of ± 2%. However, for one author who used semi-empirical equation for PDDs calculation, the mean percent variation between measured PDDs and that of the author was -3.23%, 4.69% and 5.88% for 10×10 cm2, 25×25 cm2 and 30×30 cm2 field sizes of Co-60 beam respectively, which were within acceptable limit of ±10%. A noticeable increase in PDDs was observed with increase of the field size at given depth which shows obvious contribution of secondary scattered radiation. Also measured PDDs were well matched with that of published PDDs of most of the authors i.e. ± 2%, but the measured PDDs were moderately matched with that of PDDs for only one author for some field sizes and some depths i.e. ±10%, which need to be rectified by taking more such data.
Note: This article has supplementary file(s).
Article Metrics:
Last update:
As an article writer, the author has the right to use their articles for various purposes, including use by institutions that employ authors or institutions that provide funding for research. Author rights are granted without special permission.
Author who publishes a paper at Journal of Physics and Its Applications (JPA) has the broad right to use their work for teaching and scientific purposes without the need to ask permission, including: used for (i) teaching in the author's class or institution, (ii) presentation at meetings or conferences and distributing copies to participants ; (iii) training conducted by the author or author's institution; (iv) distribution to colleagues for research use; (v) use in the compilation of subsequent authors' works; (vi) inclusion in a thesis or dissertation; (vi) reuse of part of the article in another work (with citation); (vii) preparation of derivative works (with citation); (viii) voluntary posting on open websites operated by authors or author institutions for scientific purposes (follow the CC BY-SA License).
Authors and readers can copy and redistribute material in any media or format, and mix, modify, and build material for any purpose but they must provide appropriate credit (provide article citation or content), providing links to the license, and indicate if there are changes.
The authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Journal of Physics and Its Applications (JPA). Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms and any other similar reproductions, as well as translations.
Reproduce any part of this journal, its storage in the database or its transmission by all forms or media is permitted does not need for written permission from JPA. However, it should be cited as an honor in academic manners
JPA and the Department of Physics Diponegoro University and the Editor make every effort to ensure that there are no data, opinions, or false or misleading statements published in JPA. However, the content of the article is the sole and exclusive responsibility of each author.
The Copyright Transfer Form can be downloaded here: [Copyright Transfer Form JPA]. The copyright form should be signed originally and send to the Editor in the form of printed letters, scanned documents sent via email or fax.
Dr. Eng. Ali Khumaeni, M.E. (Editor in Chief)
Editorial Office of Journal of Physics and Its Applications (JPA)
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University
Journal of Physics and Its Applications (JPA) (e-ISSN: 2622-5956) is published by the Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Indonesia under Creative Commons Attribution-ShareAlike 4.0 International License.