@article{JPLP29407, author = {Alfino Sidiq and Tiara Larashinta and Gervacia Ratnawati and Ratih Indrawati and Slamet Slamet and Hendra Sungkawa}, title = {Uji Recovery Alat Rayto RT-1904C terhadap Pemeriksaan Glukosa Metode GOD-PAP}, journal = {Jurnal Pengelolaan Laboratorium Pendidikan}, volume = {9}, number = {1}, year = {2026}, keywords = {Glucose, GOD-PAP, Internal Quality Control, Recovery, Rayto RT-1904C}, abstract = { Background: The accuracy of blood glucose testing is crucial in clinical diagnostics. A recovery test is a key validation parameter for evaluating the performance and reliability of an analytical instrument. This study aimed to evaluate the performance of the Rayto RT-1904C analyzer for glucose testing using the GOD-PAP method via a recovery test. Methods: This true experimental study used glucose standard samples spiked into normal and abnormal control serum at three concentrations (1%, 2%, 3%). Each concentration was measured with 9 replicates using the Rayto RT-1904C analyzer. The recovery percentage was calculated by comparing the measured value to the target value. Statistical analysis used the Mann-Whitney test. Results: The mean recovery percentages for normal control serum at 1%, 2%, and 3% concentrations were 95.81%, 98.59%, and 95.47%, respectively. For abnormal control serum, the mean values were 103.02%, 101.49%, and 97.70%. All values were within the acceptable range of 95-105%. Although the Mann-Whitney test showed a significant difference (p<0.05) between the two serum types, the instrument's performance is clinically acceptable. Conclusion: The Rayto RT-1904C analyzer demonstrated good accuracy and reliability for glucose testing with the GOD-PAP method, as evidenced by recovery values that met standard criteria. }, issn = {2654-251X}, pages = {1--8} doi = {10.14710/jplp.9.1.1-8}, url = {https://ejournal2.undip.ac.id/index.php/jplp/article/view/29407} }
Refworks Citation Data :
Background: The accuracy of blood glucose testing is crucial in clinical diagnostics. A recovery test is a key validation parameter for evaluating the performance and reliability of an analytical instrument. This study aimed to evaluate the performance of the Rayto RT-1904C analyzer for glucose testing using the GOD-PAP method via a recovery test. Methods: This true experimental study used glucose standard samples spiked into normal and abnormal control serum at three concentrations (1%, 2%, 3%). Each concentration was measured with 9 replicates using the Rayto RT-1904C analyzer. The recovery percentage was calculated by comparing the measured value to the target value. Statistical analysis used the Mann-Whitney test. Results: The mean recovery percentages for normal control serum at 1%, 2%, and 3% concentrations were 95.81%, 98.59%, and 95.47%, respectively. For abnormal control serum, the mean values were 103.02%, 101.49%, and 97.70%. All values were within the acceptable range of 95-105%. Although the Mann-Whitney test showed a significant difference (p<0.05) between the two serum types, the instrument's performance is clinically acceptable. Conclusion: The Rayto RT-1904C analyzer demonstrated good accuracy and reliability for glucose testing with the GOD-PAP method, as evidenced by recovery values that met standard criteria.
Article Metrics:
Last update:
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Jurnal Pengelolaan Laboratorium Pendidikan and Laboratorium Technical Service Unit Integrated Laboratory Diponegoro University as publisher of the journal.
Copyright encompasses exclusive rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms and any other similar reproductions, as well as translations. The reproduction of any part of this journal, its storage in databases and its transmission by any form or media, such as electronic, electrostatic and mechanical copies, photocopies, recordings, magnetic media, etc. , will be allowed only with a written permission from Jurnal Pengelolaan Laboratorium Pendidikan and Laboratorium.
Jurnal Pengelolaan Laboratorium Pendidikan was published Technical Service Unit Integrated Laboratory Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Jurnal Pengelolaan Laboratorium Pendidikan are sole and exclusive responsibility of their respective authors and advertisers.
Jurnal Pengelolaan Laboratorium Pendidikan (JPLP, e-ISSN: 2654-251X) is published by Persatuan Pranata Laboratorium Pendidikan Universitas Diponegoro.Unit Pelaksana Teknis (UPT) Integrated Laboratory, Universitas Diponegoro Jl. Prof. Soedarto, S.H. Tembalang, Semarang, Jawa Tengah, Indonesia 50275Phone: +6281321906666Email: jplp@live.undip.ac.id View statistics